video or message screen digital clock led display P8 outdoor led display
Technical parameters | UNIT | Parametersvalues | ||
Viewing angle | ° | H140 V120 | ||
Option distance | M | 8-120 | ||
Driving device | 2016/5020 | |||
Every square metre module | PC | 30.5 | ||
Maximum power | W | 950 | ||
Frame Frequency | ≥60 | |||
Refresh frequency | ≥320 | |||
Equilibrium brightness | CD | ≥7000 | ||
Working environment temperature | ℃ | -10~60 | ||
Working environment humidity | 10%~70% | |||
Display working voltage | AC46~54HZ,220V±15%/110V±15% | |||
Colour temperature | 9500K-11500K | |||
Gray scale/color | ≥16.7M color | |||
Input signal | RF\ S-Video\ RGB etc | |||
Control system | PCTV nonlinearity card, DVI display card,Linsn control system | |||
Mean free error time | >5000 | |||
Life | Hour | 100000 | ||
Lampfailure frequency | <0.0001 | |||
Antijam | IEC801 | |||
Safety | GB4793 | |||
Resist the electricity | 1500V last 1minNo breakdown | |||
die cabinet weight | KG | 45(standard steel box) | ||
Earth leakage current | 3.5mA | |||
IPrating | The back IP65,The front IP65 | |||
Steel box size | MM | L1024XH768X120 |
FAQ:
Why the lead time of outdoor screen is longer ?
(1)materials purchase: the purchase term of LED lamps is longer, special imported chips, the lead time takes 4-6 weeks
(2)complicated producing technics : need PCB design, cover making, glue filling, white balance adjust, etc
(3)strict structure requirements: design for cabinet, need to consider windproof, rainproof, lightningproof , etc.
How to help client choose suitable display ?
(1)the needs of displaying content
(2)visible distance,, visual angle confirm
(3) requirements of cabinet resolution
(4)requirements of installation environment
(5)cost control
What factors should be taken into consideration of screen size design ?
-There is three important factors in designing screen size:
(1)need of displaying content
(2) conditions of field and space
(3) unit template size (indoor display) or pi, xel size (outdoor display)
What are the index on the power consume and the requirements for the power supply OF THE LED screen?
The power consume of the LED screen have the Average power consume and the Maximum power consume.
We also called the Average power consume as the Working power consume, it’s the factual power consume when
it’s operating normally. The Maximum power consume is the power consume when it’s starting or full lighting and
the other extreme situations. The Maximum power consume is the necessary factor to consider when using the
AC electricity power supply, the depth of the wire and the switch, too. Generally, the Average power consume
is one out of three of the Maximum power consume.The LED display screen is the big size precision equipment.
To operate in security and stability, the AV 220V power supply input port of the LED display screen or the connected
computers’ power supply input port need to connect with the ground.Noted: computers’ power supply input port also
must be connected with the body of the computer.
What are the installation requirements of the LED display screen?
Power supply: the power supply connector must be match for the size of the LED display screen.
220V electricity power supply, live wire, neutral/null wire and the earth wire.
380V electricity power supply, three live wires, neutral/null wire and the earth wire.
The intercept area of the live wire is the same as the null.