1, short-circuit detection method, the multimeter to the short-circuit detection block (generally has the alarm function, such as the guidance of the general rule issued a tweet), detect whether there is a short-circuit phenomenon, found that short-circuit should be immediately resolved, short-circuit phenomenon is the most common LED display module failure. Some can be found by observing the IC pins and pin pins. Short-circuit detection should be done in the case of circuit power failure to avoid damage to the multimeter. This method is the most commonly used method, simple and efficient. 90% of faults can be detected by this method.
2, the Resistance detection method, the multimeter to the resistor file, to detect a normal circuit board of a point to the ground resistance value, and then detect another piece of the same circuit board of the same point test and the normal resistance value is different, if different then determine the scope of the problem.
3, the voltage detection method, the multimeter to the voltage file, to detect the suspected problematic circuit of a point to the ground voltage, the comparison is similar to the normal value, you can easily determine the scope of the problem.
4, the Pressure drop detection method, the multimeter to the diode pressure drop detection file, because all the IC is composed of a large number of single components, only miniaturization, so when it has a pin on the current through, there will be a voltage drop on the pin. Generally the same type of IC on the same pin pressure drop similar, according to the PIN pressure drop value is good or bad, the circuit must be operated in the case of power outages.